Canis – ONH 1~10K-11

Offer limits

Category:

Key Features

 True double-conversion

 Microprocessor control optimizes reliability 

• Input power factor correction 

• Output power factor 0.8

• Wide input voltage (110 V – 300 V) 

• Converter mode available

 ECO mode for energy saving  (Only available for 1-3KVA)

• Generator compatible 

 Adjustable battery number only available for 6K and up models

 Smart SNMP works well with either USB or RS-232 together

• Comprehensive display allows easy monitoring and access of UPS

   status

• Optional isolation transformer available. (Please check sales 

   directly)

Specifications

   Model ONH – 1K/11(L) ONH – 2K/11(L) ONH – 3K/11(L) ONH – 6K/11(L) ONH – 10K/11(L)  
 Phase Single phase with ground
            Capacity 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W 6000 VA / 4800 W 10000 VA / 8000 W
            INPUT
Nominal Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC
 Input Voltage Range 55-150 VAC or 110-300 VAC (Based on load at 50%) 110-300 VAC (Based on load at 50%)
85-140VAC or 160-280VAC (Based on load at 100%) 176-300 VAC (Based on load at 100%)
 Frequency Range 40Hz  ~ 70 Hz 46~54 Hz or 56~64 Hz
 Power Factor ≧ 0.99 @ Nominal Voltage (100% load)
            OUTPUT
 Output Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC
 Voltage Regulation ± 1%
  Frequency Range 47~ 53 Hz or 57 ~ 63 Hz 46~54 Hz or 56~64 Hz
 (Synchronized Range)
 Frequency Range 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz or 60Hz ± 0.1 Hz
  (Batt. Mode)
 Current Crest Ratio 3:01
 Harmonic Distortion ≦ 3 % THD (Linear Load) ≦ 3 % THD (Linear Load)
≦ 6 % THD (Non-linear Load) ≦ 5 % THD (Non-linear Load)
AC Mode to Battery Mode Zero
(transfer time)
  Inverter to Bypass 4 ms (Typical) Zero
     (transfer time)
Waveform (Batt. Mode) Pure Sinewave
            EFFICIENCY
        AC Mode 88% 88% 90% 92% 93%
      Battery Mode 83% 85% 88% 90% 91%
            BATTERY (Standard Model)
      Battery Type 12 V / 9 AH 12 V / 9 AH 12 V / 9 AH 12 V / 9 AH
        Numbers 2 4 6 16 / 20 16 / 20
  Typical Recharge Time 4 hours recover to 90% capacity 9 hours recover to 90% capacity
 Charging Current (max.) 1A 1A/2A
 Charging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 218.4 VDC ±1% 218.4 VDC ±1%
 273 VDC ±1% 273 VDC ±1%
            BATTERY (Long-run Model)
 Battery Type Depending on the capacity of external batteries
         Numbers 02-mar 04/06/2008 06-ago 16 ~ 20 (Adjustable)
 Charging Current (max.) 1A/2A/4A/6A (Adjustable) 1A/2A/4A/6A (Adjustable,
6A is only available for 16pcs batteries)
Charging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 273 VDC ±1% (Based on 20pcs batteries)
41.0VDC ± 1% 82.1 VDC ±1% 109.4VDC ±1%    
  109.4VDC ±1%      
            INDICATORS
            LCD Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
            ALARM
 Battery Mode Sounding every 4 seconds
  Low Battery Sounding every second
     Overload Sounding twice every second
         Fault Continously sounding
            PHYSICAL (Standard Model)
  Dimension, 282 x 145 x 220 397 x 145 x 220 421 x 190 x 318 369 x 190 x 688 442 x 190 x 688
D x W x H (mm)
 Net Weight (kgs) 9.8 17 27.6 61 74/66 / 76
            PHYSICAL (Long-run Model)
 Dimension, 282 x 145 x 220 397 x 145 x 220 369 x 190 x 318 442 x 190 x 318
D x W x H (mm
 Net Weight (kgs) 4.1 6.8 7.4 12 16
            ENVIRONMENT
            Humidity 20-90 % RH @ 0- 40°C (non-condensing) 0-95%RH@0-50°C 0-95%RH@0-40°C
(non-condensing) (non-condensing)
  Noise Level Less than 50dBA @ 1 Meter Less than 55dBA Less than 58dBA
 @ 1 Meter @ 1 Meter
           MANAGEMENT
 Smart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser

Downloads