Canis – ONH 10~30K-33(L)

Offer limits

Category:

Key Features

• True double-conversion

 DSP technology guarantees high performance

• Output power factor 0.9

• Active power factor correction in all phases

• 50Hz/60Hz frequency converter mode

• ECO mode operation for energy saving (ECO)

• Accepts dual-mains inputs (only for 10K/15K/20K models)

• Emergency power off function (EPO)

• Generator compatible

• SNMP+USB+RS-232 multiple communications

• 3-stage extendable charging design for optimized battery performance

• Adjustable battery numbers

• Maintenance bypass available

• Optional N+X parallel redundancy

• Optional isolation transformer offers full isolation and complete common

mode noise rejection

Specifications

         Model ONH – 10K/33(L) ONH – 15K/33(L) ONH – 20K/33(L) ONH – 30K/33(L)
         Phase 3 phase in / 3 phase out
         Capacity 10000 VA / 9000 W 15000 VA / 13500 W 20000 VA / 18000 W 30000 VA / 27000 W
         INPUT
         Nominal Voltage 3 x 400 VAC (3Ph+N)
         Voltage Range 190-520 VAC (3-phase) @ 50% load
305-478 VAC (3-phase) @ 100% load
         Frequency Range 46~54 Hz or 56~64Hz
         Power Factor ≧ 0.99  @ 100% load
         OUTPUT
         Output Voltage 3 x 400 VAC (3Ph+N)
         AC Voltage Regulation (Batt. Mode) ± 1%
         Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
         Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
         Current Crest Ratio 3:1 (max.)
         Harmonic Distortion ≦ 2 % THD (Linear Load)
≦ 5 % THD (Non-linear Load)
Transfer

Time

 AC Mode to Batt. Mode zero
 Inverter to Bypass zero
         Waveform (Batt. Mode) Pure Sinewave
         EFFICIENCY
         AC Mode 90.5% 91.5% 91.5% 92.1%
         ECO Mode 96%
         Battery Mode 87% 88% 88% 89%
         BATTERY
Standard

Model

Battery Type 12 V / 9 AH
Numbers 20 pcs (18 – 20

adjustable)**

20 pcs (18 – 20 adjustable)**

x 2 strings

20pcs (18-20adjustable)

** x 3 strings

Typical Recharge Time 9 hours recover to 90% capacity
Charging Current (max.) 1A 2A 2A 4A
Charging Voltage 273 VDC ± 1%
Long-run

Model

Battery Type Depending on the capacity of external batteries
Numbers
Charging Current (max.) 4A 4A 4A 12A
Charging Voltage 273 VDC ± 1%
         INDICATORS
         LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
         ALARM
         Battery Mode Sounding every 4 seconds
         Low Battery Sounding every second
         Overload Sounding twice every second
         Fault Continuously sounding
         PHYSICAL
Standard

Model

Dimension, D * W * H (mm) 815 x 250 x 826 815 x 250 x 826 815 x 250 x 826 815 x 300 x 1000
Net Weight (kgs) 109 164 164 233.5
Long-run

Model

Dimension, D * W * H (mm) 592 x 250 x 826 592 X 250 X 826 592 X 250 X 826 815 x 250 x 826
Net Weight (kgs) 38 40 40 64
         ENVIRONMENT
         Operation Humidity 0-95 % RH @ 0- 40°C (non-condensing)
         Noise Level < 60dB @ 1 Meter < 65dB @ 1 Meter
         MANAGEMENT
         Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, 7/8, Linux and MAC
         Optional SNMP Power management from SNMP manager and web browser

Downloads